PH Meter 001 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool

€ 21,95
+ € 13,99 Versand

PH Meter 001 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool

  • Marke: Unbranded
Verkauft von:

PH Meter 001 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool

  • Marke: Unbranded
UPE: € 42,95
Preis: € 21,95
Sie sparen: € 21,00 (48%)
Verkauft von:
€ 21,95
+ € 13,99 Versand

Auf Lager

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

PH Meter 001 High Precision for Water Quality Tester with 0-14 Measurement Range Suitable Aquarium Swimming Pool PH Meter 0.01 PH High Precision Water Quality Tester with 0-14 PH Measurement Range, Suitable for Aquarium, Swimming Pool, Indoor Outdoor Digital PH Meter Water Tester The product has been calibrated before leaving the factory, and can be used directly after receiving the package, and then calibrated according to the situation It's not only ideal for household or laboratory use, also suitable for testing pH balance of drinking water, pool, aquarium, food Project, RO system, Spa, or hydroponics. Specifications: Measuring range: 0.00-14.00 pH Resolution: 0.01 pH Accuracy: 0.01 pH Batteries: 2X 1.5V LR44(included) Automatic temperature compensation: 0-50Centigrade(32-122It) Dimensions: 15x2.5x1.3cm/6x1.1x0.5 inch Net Weight: 52g/1.83 oz Warm tips It STEP 1: Turn open pH meter, Clean the electrode in distill water It STEP 2: Immerse the electrode in pH 6.86 standard buffer solution It STEP 3: Press the "CAL" button. Wait until the display digital is 6.86pH and steady It STEP 4: Clean the electrode in distill water and dry it, immerse the electrode in Ph 4.00 standard buffer solution It STEP 5: Press the "CAL" button. Wait until the display digital is 4.00pH. Then complete pH 4.00 calibration It STEP 6: Clean electrode and dry it, put the meter into PH 9.18 standard buffer solution. Check if reading is correct between 9.17-9.19pH Instructions for use of PH calibration powder: Calibration powder: pH standard solid substance. It can be used after adding water. Suitable for the calibration of any type of ph meter. Each package can prepare 250ML standard solution. (Be sure to add water according to the required ratio, otherwise it will affect the accuracy of the calibration and increase the error) Precautions: Please note that the PH pen probe is a glass product and is a fragile product. Please do not collide with things. Once the damage is not replaceable, you must protect the probe. After use, use absorbent paper to gently absorb the water on the probe. Matters needing attention: PH meter has been calibrated before delivery, the buyer does not need to re-calibrate after receiving the goods! In the following cases, the PH meter must be re-calibrated: 1. Has been used for a long time after calibration; 2. Special electrode use Frequently; 3. The measurement accuracy requirements are relatively high. Standard configuration 1XPH meter with opp bag 2X LR44 Button batteries 1X instruction manual Questions & Answers: 1. Q: How often should I calibrate my ph meter pen ? A: One calibration can last for about half a month. When the electrode exposed to air for extended period of time, users should calibrate it. When testing polluted water quality, more frequent calibration is required to ensure the accuracy of the test value 2. Q: Can I test two kinds of water without calibrating ? A : Yes , but when testing the liquid that is not pure water or distilled water, after the test, you need to put it in pure water or distilled water, wash it and wipe it dry, and then test the next liquid (to ensure the accuracy of the value of the next test liquid) 3. Q: Why my ph meter switch and digital display are not sensitive ? A: It might be caused by low battery. Just replace the battery and it will work again. 4. Q: Can I use this to test Urine A: Yes , it can. The test liquid must not be corrosive, which will damage the accuracy of the glass probe and shorten the service life of the glass probe. 5. Q: What if the calibration result is wrong? A: Assuming that the calibration result is wrong, the pen recognizes ph 9.18 or ph 4.01 after calibrating ph 6.86 . Step 1: Take 50ml of purified water or distilled water, and then import one pack of 6.86 calibration powder, stir evenly, put the PH pen probe in water for One Hours. Step 2: Then turn on the pen, press and hold the CAL button for five seconds, then let go, the value flashes, and the END calibration is completed. Except the ways above, you could long press the switch and calibration keys at the same time for five seconds, restore the factory settings, and then test. ( The test difference might within 2% with reset control , and the powder calibration's test difference is within 0.1%-1% ) _x000D_ _x000D_
  • Fruugo-ID: 416141169-878232978
  • EAN: 839873465421

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Produktsicherheitsetiketten

CE Mark
Sicherheitswarnungen: WARNING! TO AVOID DANGER OF SUFFOCATION,KEEP AWAY FROM BABIES ANDCHILDREN. DO NOT USE IN CRIBS/BEDSOR PLAY PENS.THIS BAG IS NOT ATOY.
Zutaten: Octinoxate 6.1%
Teilenummer des Herstellers: MPN839873465421
Modellnummer: MN839873465421
Seriennummer: SN839873465421
Chargennummer: BN839873465421

Lieferung und Rückgaben

Versand innerhalb von 3 Tagen

  • STANDARD: € 13,99 - Lieferung zwischen Fr. 31 Oktober 2025–Di. 11 November 2025

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • Wuhanzisetongkongdianzishangwuyouxiangongsi
  • Wuhanzisetongkongdianzishangwuyouxiangongsi
  • No. S00357, 2nd Floor, E-commerce Office Building, Building 1, No. 58, Guanggu Avenue,
  • Donghu New Technology Development Zone
  • Wuhan
  • CN
  • 430074
  • qian58qicuzhi0@126.com
  • (+86)15812056096
  • https://www.fruugo.com

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • Axitera GmbH
  • Axitera GmbH
  • Kreuznacher Str. 30, D-60486 Frankfurt am Main, Hessen, Germany
  • Frankfurt am Main
  • DE
  • 60486
  • successservice3@gmail.com
  • (+49) 6934873848