Specification:  Temperature control range: -50℃ ~ 110℃.  Temperature measurement error: ± 0.5℃.  Sensor Model: NTC (10K / 3435).  Control accuracy: 1℃.  Working voltage: DC12V / DC24V / AC220V.  Working current: MAX200mA.  Relay contact current: AC5A / 220V.  Data saved: Yes.  Operating temperature: 0℃ ~ 50℃.  Storage temperature: -10℃ ~ 60℃.  Instrument size: 90mm (length) x 60mm (width) x 26.5mm (depth).  Opening size: 70mm (length) x 50mm (height).  Delivery probe length of 1 meter, probe size: φ4mm x 20mm.     Function:  Control temperature setting:  Press Set button once, the temperature display flashes long press 3 seconds to enter the setup menu, that is, the code HC.  Press △ key or ▽ key to cycle through the code of HC-D-LS-HS-CA-PT-AH-AL. To enter a code, press Set and press △ or ▽ key to change the desired value Exit automatically after 5 seconds.  Heating control: when mode control mode (code HC) is set to H, it is heating mode. For example, set the control heating temperature to 35℃ and the temperature hysteresis to 2 degrees. When the ambient temperature ≤ set temperature (35℃) - back to the difference (2℃) 33℃ relay output starts; when the ambient temperature ≥ set temperature (35℃) relay output is turned off.  Refrigeration control: Mode control mode (code HC) is set to C cooling mode, for example, set the cooling 35℃, temperature, hysteresis of 2 degrees. The relay output is activated when the ambient temperature is over the set temperature (35℃) + hysteresis (2℃) at 37℃. The relay output is turned off when the ambient humidity is below the set humidity (35℃).  HC: mode selection, C for cooling mode. H stands for heating mode.  D: hysteresis, when in heating mode start temperature = display temperature; - hysteresis. Start temperature when in cooling mode = display temperature + hysteresis.  PU: delay start, when the relay stops output starts timing, the interval between the next start must be greater than the delay start time, to avoid frequent start.  HS: temperature upper limit alarm; when the temperature exceeds the alarm upper limit, the digital tube shows 'HHH' temperature is lower than the alarm setting, it will automatically exit the alarm.  LS: temperature lower limit alarm; when the temperature exceeds the alarm lower limit, the digital tube will display "LLL" temperature is higher than the alarm setting, it will automatically exit the alarm.  CA temperature calibration: temperature calibration straight plus display humidity straight, for example: temperature display 35℃ calibration temperature increase of 5℃ then the display temperature should be 40℃.  Reset: press the left up and down keys do not let go, the screen displays 888, you can restore the factory settings.  PT: Delay start For example: 1 minute delay When the temperature reaches the set value after the relay to be delayed for 1 minute to start.  AH: Over-temperature alarm: For example: over-temperature alarm temperature setting 50 degrees, when the temperature is greater than or equal to 50 degrees buzzer alarm.  AL: Low temperature alarm: For example: low temperature alarm temperature setting 20 degrees, when the temperature is less than or equal to 20 degrees buzzer alarm.
  • Fruugo-ID: 190943529-407440898
  • EAN: 4250937722506

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Sicherheitswarnungen: Not suitable for children under 36 months, The parcel bag is not a toy. Keep away from children to avoid suffocation hazards.

Lieferung und Rückgaben

Versand innerhalb von 2 Tagen

  • STANDARD: € 7,49 - Lieferung zwischen Mi. 22 Oktober 2025–Mo. 03 November 2025

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • GreenZech
  • Shenzhen GreenZech Technology Co.,Ltd
  • 16C B97 Fuxuan Dalong Jiedao Longhua District
  • Guangdong China
  • Shenzhen
  • CN
  • 518000
  • 1158738758@qq.com
  • 14774955154

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM.1,PLANTA 1,DERECHA
  • OFICINA 3,Fuenlabrada
  • Madrid
  • ES
  • 28947
  • successservice3@gmail.com
  • +34 910602659