Dc5v Transistor Tester 1.77in Tft Color Screen Capacitance Inductance Esr Volt Frequency Meter

€ 26,95
+ € 1,49 Versand

Dc5v Transistor Tester 1.77in Tft Color Screen Capacitance Inductance Esr Volt Frequency Meter

  • Marke: Unbranded
Verkauft von:

Dc5v Transistor Tester 1.77in Tft Color Screen Capacitance Inductance Esr Volt Frequency Meter

  • Marke: Unbranded
Preis: € 26,95
Verkauft von:
€ 26,95
+ € 1,49 Versand

Momentan nicht verfügbar

Wir wissen nicht, wann oder ob dieser Artikel wieder auf Lager sein wird.

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

Item Type: Transistor TesterMaterial: PCBModel: GM328AInput Voltage: DC5V Type C Power SupplyWorking Voltage: About 30mAPlug In Measurement: SupportPatch Measurement: SupportNegative With Power: Without BatteryControl Method: EncoderDisplay Screen: 1.77 Inch TFT Color ScreenProduct Description.Rotating coding switch has 6 operation methods: short press, long press, left rotation, right rotation, press and hold left rotation, press and hold right rotation.Press it in the off state to turn on the power and start testing.If the device is not detected after one test. Press and hold the switch or turn the switch left or right to enter the function menu. Once you enter the function menu, you can select the left and right switches above or below the menu item. To enter a function item, press the switch briefly. When you need to exit a function, press and hold the switch.1. Tester calibration is used to eliminate the errors of its own components and make the final test results more accurate. Calibration is divided into quick calibration and full function calibration.2. Quick calibration operation method: use the wire to short three test points TP1, TP2, TP3, then press the test button, while observing the screen. The screen color will change to white on black and the message "Selftest mode...?" will appear. will appear, press the test key to enter the fast calibration process; if the prompt "Self test mode...?" appears, if no key is pressed within 2 seconds, the normal test process will be entered, and the wire resistance values of the shorted TP1, TP2 and TP3 test points will be displayed at the end. After entering the quick calibration process, some data will appear on the screen, regardless. Wait until a flashing string appears on the screen"Isolating Probe!" After that, remove the shorted TP1, TP2 and TP3 wires. Wait until the "Test End" string appears on the screen and the quick calibration is complete. For the first calibration, use the full function calibration mode.3. Full function calibration requires access from the function menu and an additional 220nf capacitor. Full function calibration performs a more comprehensive calibration process and takes longer. Once in the function menu, turn the test button to the "Selftest" menu item and press the test button again to enter the full function calibration process. The flashing string "short Probes!" appears on the screen first, and then, like a quick calibration, you short the three test points with wires and wait for the calibration process. The flashing string "Isolated Probes!" appears on the screen When the string "1 - | | - 3>100nf" appears on the screen, the prepared 220nf capacitors are installed on the test points TP1 and TP3. Wait until the screen prompts "Test End" to complete the fully functional calibration process. .wang-edit-text{ font-family:'Arial' !important; } .wang-edit-text table { border-top: 1px solid #000; border-left: 1px solid #000; } .wang-edit-text table td, .wang-edit-text table th { border-bottom: 1px solid #000; border-right: 1px solid #000; padding: 3px 5px; } .wang-edit-text table th { text-align: center; } 1Digital LCD display: Transistor tester is easy to read, displaying measurement data and graphs, rotating switch control, convenient button measurement. 2Frequency Measurement: Press and hold the test button to exit the frequency measurement function. Frequency measurement range from 1Hz to more than 1MHz When the measured frequency is lower than 25KHz, the period is displayed. 3Square Wave Generator: Multi range square wave frequency, rotate the left and right test button to switch different square wave frequencies, long press the test button to exit the square wave generator. 4Pulse Generator: Turn the test button to the left or right to adjust the pulse duty cycle from 1% to 99%. Press and hold the test button to exit the pulse generator. 5Power Interface: The transistor tester uses 5V Type C power interface for power supply, or it can be soldered to 9V battery interface for automatic shutdown, and the shutdown current is only about 20nA.
  • Fruugo-ID: 158740069-336716825
  • EAN: 4511935609955

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Produktsicherheitsetiketten

CE Mark
Sicherheitswarnungen: Please use and store the product correctly according to the instructions

Lieferung und Rückgaben

Versand innerhalb von -1 Tagen

  • STANDARD: € 1,49 - Lieferung zwischen Mi. 08 Oktober 2025–Mo. 20 Oktober 2025

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • Shenzhen Yangxi Trading Co., Ltd.
  • Shenzhen Yangxi Trading Co., Ltd.
  • No. 203, No. 3, Lane 3, Houshan West, Xiaxue Village, Xinxue Community, Bantian Street, Longgang
  • Shenzhen
  • CN
  • 518129
  • wqvkk3@163.com

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • SUCCESS COURIER SL
  • SUCCESS COURIER SL
  • CALLE RIO TORMES NUM. 1, PLANTA 1, DERECHA, OFICINA 3, Fuenlabrada, Madrid, 28947 Spain
  • Frankfurt am Main
  • ES
  • 28947
  • successservice2@hotmail.com
  • 34910602659