2-Channel RS485 Repeater with Photoelectric Isolation and 9-36VDC Input for Industrial Use Edition 1107

€ 19,22
+ € 9,59 Versand

2-Channel RS485 Repeater with Photoelectric Isolation and 9-36VDC Input for Industrial Use Edition 1107

  • Marke: Unbranded
Verkauft von:

2-Channel RS485 Repeater with Photoelectric Isolation and 9-36VDC Input for Industrial Use Edition 1107

  • Marke: Unbranded

€ 19,22

Bespaar € 26,30 (57%)

UVP

€ 45,52
Auf Lager
+ € 9,59 Versand
Verkauft von:

€ 19,22

Bespaar € 26,30 (57%)

UVP

€ 45,52
Auf Lager
+ € 9,59 Versand

Wir akzeptieren die folgenden Zahlungsmethoden

Beschreibung

Usage Tips:Feature: 1. Complete Isolation of Communication: The repeater module adopts an industrial-grade design, providing complete communication isolation, stable and reliable performance, with a transmission rate up to 300Kbps. 2. Isolated Power Module: The repeater module includes a built-in high-performance DC-DC isolated power module, achieving electrical isolation between ports. 3. 2-Channel Output: The repeater module supports 2-channel output for multi-device communication, allowing up to 256 nodes per channel, with extended transmission distance. 4. Automatic Control Technology: The 2-channel repeater features automatic data flow control technology, which automatically detects and manages data transmission direction. 5. Multiple Protection Measures: The 2-channel repeater provides ±15kV ESD protection, 600W dual TVS surge protection, and 2.5kV communication isolation. 6. Wide Power Supply Range: The 2-channel repeater supports a wide input voltage range of 9–36V DC, includes reverse polarity protection, and is designed for standard rail mounting. Specification: Item Type: Repeater Module Material: PP Operating Voltage: Typical Value: DC 9–36V Limit Value: DC 40V Power Rating: Typical: 0.36W (9V/35mA; 12V/27mA; 24V/15mA) Limit Value: 0.5W Operating Environment: Typical: Temperature: -30°C to 80°C, Humidity: > 95% RH Limit Value: -40°C to 85°C Isolation Voltage: Typical: 2000V Limit Value: 2500V Interface Protection: Typical: 600W Thunder Surge Limit: 600W Load Capacity: Typical: 1–128 Nodes Limit: 256 Nodes Communication Distance: Typical: 0–1500m Limit: 2000m Communication Speed: Typical: 300bps–115.2Kbps Limit Value: 300Kbps Size: Approx. 100 x 54 x 32mm / 3.9 x 2.1 x 1.3in Status Indicators: Power Indicator: Red, remains on after power is connected Data Indicator: Green, blinks when data is transmitted on the bus Terminal Interface Definition: VCC: Power supply interface (DC 9–36V) GND: Negative power terminal 485 A: RS485 signal input/output positive terminal 485 B: RS485 signal input/output negative terminal 485 A2: Second RS485 signal input/output positive terminal 485 B2: Second RS485 signal input/output negative terminal GND: Isolated RS485 terminal ground, can be connected to earth or shield wire 485 A1: First RS485 signal input/output positive terminal 485 B1: First RS485 signal input/output negative terminal Usage Instructions: A. RS485 Wiring Notes: 1. Use shielded twisted-pair cable for RS485 communication lines, preferably with spare strands; total length should not exceed 1500 meters. 2. Keep wiring away from high-voltage power lines; avoid parallel routing or bundling with power cables. 3. RS485 bus must use a daisy-chain (hand-in-hand) topology; star or branched connections are not recommended. 4. For systems with more than 30 controllers or cable runs over 500 meters, use of an RS485 repeater is recommended. 5. Equipment powered by AC must have proper chassis grounding. 6. Connect the GND terminals of all RS485 devices using shielded wires. B. RS485 Cable Selection Requirements: Use 2-core shielded twisted-pair cable Copper conductor, wire diameter 0.5–0.75 mm² Impedance: 38–88 ohms/km Capacitance: 30–50 nF/km Twist pitch: 20 mm for 2-core shielded twisted pair (for runs under 500 meters, standards may be relaxed, but twisted pair must still be used) C. Bus Configuration Limits: The bus consists of two or more physically interconnected devices. Maximum of 256 devices allowed without repeaters, with total bus length not exceeding 1500 meters. The bus should not have branches. If branches are unavoidable: 1. Branch length must not exceed 10 meters; total bus length must not exceed 800 meters; maximum of 50 devices per branch. 2. Keep signal lines away from interference sources. Route signal lines through low-interference pathways and avoid running parallel to high-power lines (e.g., 220V) or RF cables (e.g., CATV). Maintain separation of at least 0.5 meters if parallel routing is necessary. 3. All wire joints must be securely soldered or crimped and properly sealed against moisture using waterproof tape or epoxy resin. D. Signal Common Ground: 1. All devices on the same network segment must share a common signal ground to prevent common-mode interference. 2. For centralized power supply systems, connect the negative DC terminals of all devices (including those with independent power supplies) to form a unified signal ground, which serves as the DC power ground. 3. For systems with individual power supplies, connect the ground (black wire) pins of all bus devices to establish a common reference.
  • Marke: Unbranded
  • Kategorie: Repeater & Sende
  • Breite: 5
  • Länge: 5
  • Gewicht: 0.5
  • Höhe: 5
  • Fruugo-ID: 436818650-915524068
  • EAN: 9473222559532

Produktsicherheitsinformationen

Bitte beachten Sie die unten aufgeführten spezifischen Produktsicherheitsinformationen für dieses Produkt

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Produktsicherheitsetiketten

CE Mark

Lieferung und Rückgaben

Versand innerhalb von 24 Stunden

  • STANDARD: € 9,59 - Lieferung zwischen Mo. 08 Dezember 2025–Mo. 15 Dezember 2025

Versand von China.

Wir tun unser Bestes, um dafür zu sorgen, dass die von Ihnen bestellten Produkte vollständig und gemäß Ihrer Spezifikationen an Sie geliefert werden. Wenn Sie allerdings eine unvollständige Bestellung oder Artikel erhalten, die sich von den bestellten unterscheiden, oder es einen anderen Grund gibt, warum Sie mit Ihrer Bestellung nicht zufrieden sind, können Sie die gesamte Bestellung oder einzelne darin enthaltenen Produkte zurücksenden und eine vollständige Rückerstattung für die Artikel erhalten. Vollständige Rückgaberichtlinie ansehen

Details zur Produktkonformität

Bitte beachten Sie die unten aufgeführten Konformitätsinformationen zu diesem Produkt.

Die folgenden Informationen werden vom unabhängigen Drittanbieter bereitgestellt, der dieses Produkt verkauft.

Hersteller:
Es folgen die Kontaktdaten für den Hersteller des jeweiligen Produkts, das auf Fruugo verkauft wird.

  • Shenzhenyuandedianziyuouxiangongsi
  • Shenzhenyuandedianziyuouxiangongsi
  • Room 903, Building B, Nanxian Commercial Plaza, Nanyuan New Village
  • Hongshan Community, Minzhi Subdistrict, Longhua District
  • Longhua
  • Shenzhen
  • China
  • 518500
  • szrhkj21@163.com
  • 15819859068

Verantwortliche Person in der EU:
Es folgen die Kontaktinformationen für die verantwortliche Person in der EU. Die verantwortliche Person ist der benannte Wirtschaftsteilnehmer mit Sitz in der EU und verantwortlich für die Compliance-Verpflichtungen in Verbindung mit dem jeweiligen Produkt, das in die Europäische Union verkauft wird.

  • Huang Pengliang
  • FORCHAIN GmbH
  • Vilbeler Landstra?e73 60388 Frankfurt am Main
  • Frankfurt am Main
  • Frankfurt am Main
  • DE
  • 60388
  • nnicolesusan093@gmail.com
  • 1638127736