2 Channel Isolated RS485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module 9‑36VDC

€ 28,25
FREE Shipping

2 Channel Isolated RS485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module 9‑36VDC

  • Brand: Unbranded
Sold by:

2 Channel Isolated RS485 Repeater Industrial Grade Photoelectric Isolation Type Repeater Module 9‑36VDC

  • Brand: Unbranded
RRP: € 37,85
Price: € 28,25
You save: € 9,60 (25%)
Sold by:
€ 28,25
FREE Shipping

In stock

We accept the following payment methods

Description

Specification Item Type: Repeater Module Material: PP Operating Voltage Typical Value: DC 9-36V Limit Value: DC DC40V Power Rating Typical: 0.36W (9V/35mA; 12V/27mA; 24V/15mA) Limit Value: 0.5W Operating Environment Typical: Temperature: -30℃ To 80℃ Humidity: >95%RH Limit Value: -40℃ To 85℃ Isolation Voltage Typical: 2000V Limit Value: 2500V Interface Protection Typical: 600W Thunder Surge Limit: 600W Load Capacity Typical: 1-128 Nodes Limit: 256 Nodes Communicating Distance Typical: 0-1500m Limit: 2000m Communicating Speed Typical: 300bps-115.2Kbps Limit Value: 300Kbps Size: Approx. 100 x 54 x 32mm / 3.9 x 2.1 x 1.3in The Meanings Of The Status Indicators On The Front Are As Follows: Power Indicator: Red Power Indicator, Always On After Power On Data Indication: Green Data Indicator, Blinking When There Is Data On The Bus The Interface At The Terminal Of The Wiring Column Is Defined As Follows VCC: Power Supply Interface (DC 9-36V) GND: Negative Power Supply Terminal 485 A: RS485 Signal Input Or Output Positive Terminal 485 B: RS485 Signal Input Or Output Negative 485 A2: Second RS485 Signal Input Or Output Positive 485 B2: Second RS485 Signal Input Or Output Negative GND: Isolated RS485 Terminal Ground, Can Be Connected To Earth Or shielding Wire 485 A1: First RS485 Signal Input Or Output Positive 485 B1: First RS485 Signal Input Or Output Negative How to Use: A. 485 wiring notes: 1. 485 communicating line must be shielded twisted pair, preferably with multiple spare strands, and the total length is recommended not to exceed 1500 meters. 2. The wiring should be as far away as possible from the high voltage power lines, not in parallel with the power lines, and not bundled together. 3. 485 bus must be a hand in hand bus structure, firmly eliminate the star connection and bifurcation connection. 4. More than 30 controllers or line longer than 500 meters, it is recommended that the 485 repeater must be used. 5. AC powered equipment and chassis must be real grounded, and well grounded. 6. Connect the GND ground of all 485 devices with shielded wire. B. communicating using RS485 bus wire selection requirements: Use 2-core shielded twisted pair wire Copper, wire diameter 0.5 - 0.75 square millimeters. Impedance 38 - 88 ohms / km. Capacitive resistance of 30 to 50 nF/km. Stranding distance of 20 mm of 2 core shielded twisted pair (if the distance of the line does not exceed 500 meters can be appropriately reduced line standards, but must be twisted pair) C. Bus limits: Composed of two or more devices with physical connection to each other, a maximum of 256 devices are allowed to be hooked up on the bus, and the bus length is no more than 1500 meters without adding repeaters. The system bus should not have branches, and if branches are unavoidable, the following requirements must be met: 1. the branch length is no more than 10 meters; the sum of the bus length is no more than 800 meters; the total number of devices on the branch line is recommended to be no more than 50. 2. All communicating signal lines should be as far away from the source of interference as possible, signal lines should go to the weak well, not with strong power (such as 220 volt residential power) or RF signal lines (such as CATV, large signal audio lines) parallel lines, if parallel lines, the distance should be greater than 0.5 meters. 3. All line joints must be welded or doweled tight connection, and waterproof treatment, for example, the butt welded with waterproof tape or epoxy resin sealing treatment. D. Signal common ground: 1. All devices on the same net segment must have a unified signal ground to avoid common mode interference. 2. centralized power supply, all the power supply on the same net segment (including communicating equipment with their own power) of the negative DC terminal directly connected together to form a common signal ground, the signal ground is the DC power ground. 3. When a single independent power supply, the ground (black line) pins of all bus devices on the same net segment are connected together, thus forming a common signal ground. Package List 1 x Repeater
  • Fruugo ID: 351879255-766613424
  • EAN: 9308869087745

Product Safety Information

Please see the product safety information specific to this product outlined below

The following information is provided by the independent third-party retailer selling this product.

Product Safety Labels

CE Mark
Safety Warnings: Please do not allow your child to handle this product alone to avoid swallowing or other injuries; adult supervision is recommended.

Delivery & Returns

Dispatched within 2 days

  • STANDARD: FREE - Delivery between Mon 20 October 2025–Fri 24 October 2025 - FREE

Shipping from China.

We do our best to ensure that the products that you order are delivered to you in full and according to your specifications. However, should you receive an incomplete order, or items different from the ones you ordered, or there is some other reason why you are not satisfied with the order, you may return the order, or any products included in the order, and receive a full refund for the items. View full return policy